Pandawa Logo
Journal of Multidisciplinary Applied Natural Science

##plugins.themes.gdThemes.journalSlogan##

Scopus CiteScore 2024

4.8

Calculated on 05 May, 2025

SJR 2024

0.31

Powered by scimagojr.com

##plugins.themes.gdThemes.language##

Journal of Multidisciplinary Applied Natural Science

##plugins.themes.gdThemes.general.eIssn##: 2774-3047


bol: 4 zk: 2 (2024) Articles https://doi.org/10.47352/jmans.2774-3047.211

Establishment of Typical Dose Reference Level (DRL) Values for Adult Patients Undergoing Computed Tomography in Three Hospitals in Brazzaville, Congo Republic

Guy Blanchard Dallou Philippe Ondo Meye Joël Bazoma Clobite Bouka Biona Saïdou Saïdou Germain Hubert Ben-Bolie

##plugins.themes.gdThemes.author.info##

Guy Blanchard Dallou

https://orcid.org/0000-0003-0025-2083
  • dg_blanc@yahoo.fr
  • Faculté des Sciences et Techniques, Université Marien Ngouabi, Brazzaville-BP 69 (Congo); Laboratoire de Physique Nucléaire et Applications, Institut National de Recherche en Sciences Exactes et Naturelles, Brazzaville-PB 2400 (Congo)
  • ##plugins.themes.gdThemes.author.noBiography##

##plugins.themes.gdThemes.author.info##

Philippe Ondo Meye

https://orcid.org/0000-0001-7322-5217
  • dg_blanc@yahoo.fr
  • Direction Générale de la Radioprotection et de la Sûreté Nucléaire, Ministère de l'Energie et des Ressources Hydrauliques, Libreville- BP 1172 (Gabon); Laboratory of atomic, molecular and Nuclear Physics, Department of Physics, University of Yaounde, Yaounde-812 (Cameroon)
  • ##plugins.themes.gdThemes.author.noBiography##

##plugins.themes.gdThemes.author.info##

Joël Bazoma

https://orcid.org/0000-0001-6204-4824
  • dg_blanc@yahoo.fr
  • Faculté des Sciences et Techniques, Université Marien Ngouabi, Brazzaville-BP 69 (Congo); Laboratoire de Physique Nucléaire et Applications, Institut National de Recherche en Sciences Exactes et Naturelles, Brazzaville-PB 2400 (Congo)
  • ##plugins.themes.gdThemes.author.noBiography##

##plugins.themes.gdThemes.author.info##

Clobite Bouka Biona

https://orcid.org/0000-0002-6225-081X
  • dg_blanc@yahoo.fr
  • Faculté des Sciences et Techniques, Université Marien Ngouabi, Brazzaville-BP 69 (Congo); Laboratoire de Physique Nucléaire et Applications, Institut National de Recherche en Sciences Exactes et Naturelles, Brazzaville-PB 2400 (Congo)
  • ##plugins.themes.gdThemes.author.noBiography##

##plugins.themes.gdThemes.author.info##

Saïdou Saïdou

https://orcid.org/0000-0001-7427-0239
  • dg_blanc@yahoo.fr
  • Laboratory of atomic, molecular and Nuclear Physics, Department of Physics, University of Yaounde, Yaounde-812 (Cameroon); Nuclear Technology Section, Institute of Geological and Mining Research, Yaounde-4110 (Cameroon)
  • ##plugins.themes.gdThemes.author.noBiography##

##plugins.themes.gdThemes.author.info##

Germain Hubert Ben-Bolie

https://orcid.org/0000-0002-0564-4548
  • dg_blanc@yahoo.fr
  • Laboratory of atomic, molecular and Nuclear Physics, Department of Physics, University of Yaounde, Yaounde-812 (Cameroon)
  • ##plugins.themes.gdThemes.author.noBiography##

##plugins.themes.gdThemes.publishedIn##: maiatzak 18, 2024

Laburpena

The present study aimed at to establish typical dose reference level (DRL) values for adult patients undergoing computed tomography (CT) examinations in three hospitals in Brazzaville, Congo Republic. The examinations considered were head, chest, abdomen-pelvis, chest-abdomen-pelvis and lumbar spine CT scans. For each examination, the median of the distribution for the volume CT dose index (CTDIvol) and dose-length product (DLP) were determined. The median values were considered as the typical DRL values. Hypothesis testing was also carried out to statistically compare the mean values obtained for each participating CT facility. In the case of head scan, the typical values proposed in the present study in terms of CTDIvol and DLP were 15–48% and 28–60% lower than the DRL values reported in the literature, respectively. In the case of lumbar spine, the typical value determined in this study in terms of DLP was 48–70% greater than the DRL values provided in the literature. The typical values proposed for chest, abdomen-pelvis and chest-abdomen-pelvis were within the DRL values reported in the literature. It is possible that the adoption of the typical values proposed in the present study will help in reducing the dose received by adult patients undergoing CT examination in Congo Republic.

Erreferentziak

  • [1] G. Paulo, J. Damilakis, V. Tsapaki, A. A. Schegerer, J. Repussard, W. Jaschke, G. Frija, and R. European Society of. (2020). "Diagnostic Reference Levels based on clinical indications in computed tomography: A literature review". Insights Imaging. 11 (1): 96. 10.1186/s13244-020-00899-y.

  • [2] A. D. Wrixon. (2008). "New recommendations from the International Commission on Radiological Protection--A review". Physics in Medicine & Biology. 53 (8): R41-60. 10.1088/0031-9155/53/8/R01.

  • [3] M. H. Ali, C. Anam, F. Haryanto, and G. Dougherty. (2018). "The comparison of size-specific dose estimate in CT examination based on head and body PMMA phantom". Journal of Physics and Its Applications. 1 (1). 10.14710/jpa.v1i1.3905.

  • [4] W. Huda, K. M. Ogden, and M. R. Khorasani. (2008). "Converting dose-length product to effective dose at CT". Radiology. 248 (3): 995-1003. 10.1148/radiol.2483071964.

  • [5] G. K. Korir, J. S. Wambani, I. K. Korir, M. A. Tries, and P. K. Boen. (2016). "National diagnostic reference level initiative for computed tomography examinations in Kenya". Radiation Protection Dosimetry. 168 (2): 242-52. 10.1093/rpd/ncv020.

  • [6] C. P. Dimitroukas, V. I. Metaxas, F. O. Efthymiou, C. P. Kalogeropoulou, P. E. Zampakis, and G. S. Panayiotakis. (2022). "Patient dose audit in common CT examinations". Radiation Physics and Chemistry. 19210.1016/j.radphyschem.2021.109924.

  • [7] D. Joseph Zira, T. Haruna Yahaya, M. S. Umar, B. F. Nkubli, N. C. Chukwuemeka, M. Sidi, R. Emmanuel, F. Z. Ibrahim, S. S. Laushugno, and A. P. Ogenyi. (2021). "Clinical indication-based diagnostic reference levels for paediatric head computed tomography examinations in Kano Metropolis, northwestern Nigeria". Radiography (London). 27 (2): 617-621. 10.1016/j.radi.2020.11.021.

    DOI: https://doi.org/10.1016/j.radi.2020.11.021
  • [8] J. Vassileva, M. Rehani, D. Kostova-Lefterova, H. M. Al-Naemi, J. S. Al Suwaidi, D. Arandjic, E. H. Bashier, S. Kodlulovich Renha, L. El-Nachef, J. G. Aguilar, V. Gershan, E. Gershkevitsh, E. Gruppetta, A. Hustuc, A. Jauhari, M. H. Kharita, N. Khelassi-Toutaoui, H. R. Khosravi, H. Khoury, I. Kralik, S. Mahere, J. Mazuoliene, P. Mora, W. Muhogora, P. Muthuvelu, D. Nikodemova, L. Novak, A. Pallewatte, D. Pekarovic, M. Shaaban, E. Shelly, K. Stepanyan, N. Thelsy, P. Visrutaratna, and A. Zaman. (2015). "A study to establish international diagnostic reference levels for paediatric computed tomography". Radiation Protection Dosimetry. 165 (1-4): 70-80. 10.1093/rpd/ncv116.

    DOI: https://doi.org/10.1093/rpd/ncv116
  • [9] P. O. Meye, C. Schandorf, R. Ndong, and H. Obame. (2018). "Assessment of the performance characteristics of an optically stimulated luminescence dosimetry system in Gabon". Radiation Protection and Environment. 41 (2). 10.4103/rpe.RPE_28_18.

  • [10] B. Akamba Mbembe, A. Manga, S. Mbida Mbembe, P. Ele Abiama, Saidou, P. Ondo Meye, T. C. Kofane, and G. H. Ben-Bolie. (2022). "Indoor Radon (222rn) Measurements and Estimation of Annual Effective Dose in Mvangan Locality, South Cameroon". Radiation Protection Dosimetry. 198 (20): 1565-1574. 10.1093/rpd/ncac204.

    DOI: https://doi.org/10.1093/rpd/ncac204
  • [11] S. Mbida Mbembe, B. Akamba Mbembe, A. Manga, P. Ele Abiama, Saidou, P. Ondo Meye, P. Owono Ateba, and G. H. Ben–Bolie. (2021). "Indoor radon, external dose rate and assessment of lung cancer risk in dwellings: the case of Ebolowa town, Southern Cameroon". International Journal of Environmental Analytical Chemistry. 103(17): 5957-5973. 10.1080/03067319.2021.1946684.

    DOI: https://doi.org/10.1080/03067319.2021.1946684
  • [12] J. E. Turner, D. J. Downing, and J. S. Bogard.(2012)." Statistical Methods in Radiation Physics. 10.1002/9783527646548.

  • [13] J. Bazoma, G. B. Dallou, P. Ondo Meye, C. Bouka Biona, Saidou, and G. H. Ben-Bolie. (2022). "Assessment of organ and effective doses received by adult patients undergoing computed tomography in three hospitals in Brazzaville, Congo Republic". Radiological Physics and Technology. 15 (4): 379-386. 10.1007/s12194-022-00678-y.

    DOI: https://doi.org/10.1007/s12194-022-00678-y
  • [14] P. Vaz. (2014). "Radiation protection and dosimetry issues in the medical applications of ionizing radiation". Radiation Physics and Chemistry. 104 : 23-30. 10.1016/j.radphyschem.2014.02.007.

  • [15] B. Moifo, J. R. M. Tapouh, M. N. Guena, T. N. Ndah, R. N. Samba, and A. Simo. (2017). "Diagnostic Reference Levels of Adults CT-Scan Imaging in Cameroon: A Pilot Study of Four Commonest CT-Protocols in Five Radiology Departments". Open Journal of Medical Imaging. 07 (01): 1-8. 10.4236/ojmi.2017.71001.

    DOI: https://doi.org/10.4236/ojmi.2017.71001
  • [16] R. Kanda, M. Akahane, Y. Koba, W. Chang, K. Akahane, Y. Okuda, and M. Hosono. (2021). "Developing diagnostic reference levels in Japan". Japanese Journal of Radiology. 39 (4): 307-314. 10.1007/s11604-020-01066-5.

  • [17] A. Gervaise, F. Esperabe-Vignau, M. Pernin, P. Naulet, Y. Portron, and M. Lapierre-Combes. (2011). "[Evaluation of the knowledge of physicians prescribing CT examinations on the radiation protection of patients]". Journal de Radiologie. 92 (7-8): 681-7. 10.1016/j.jradio.2011.03.023.

  • [18] K. L. Lee, T. Beveridge, M. Sanagou, and P. Thomas. (2020). "Updated Australian diagnostic reference levels for adult CT". Journal of Medical Radiation Sciences. 67 (1): 5-15. 10.1002/jmrs.372.

  • [19] P. Roch and B. Aubert. (2012). "Le point sur les niveaux de référence diagnostiques en Radiologie et médecine nucléaire en 2011". Médecine Nucléaire. 36 (7): 378-389. 10.1016/j.mednuc.2012.05.004.

  • [20] H. Delis, I. D. Mclean, and W. Van. (2013). "Dosimetry in diagnostic radiology for paediatric patients". IAEA human Health Series. 24.

##plugins.themes.gdThemes.article.info##

##plugins.themes.gdThemes.identifiers##